西门子CPU416可编程控制器 西门子CPU416可编程控制器 6ES7416-2XN05-0AB0 SIMATIC S7-400,CPU 416-2DP: 5.6MB(2.8MB代码,2.8MB数据),位处理速度30ns,集成接口:1. MPI/DP, 2. PROFIBUS DP 显示价格 6ES7416-3ES06-0AB0 SIMATIC S7-400,CPU 416-3PN: 16MB(8MB代码,8MB数据),位处理速度30ns,集成接口:1. MPI/DP, 2. PROFINET, 3. 可扩展的IF964-DP(IF1)接口 显示价格 6ES7416-3XR05-0AB0 SIMATIC S7-400,CPU 416-3DP: 11.2MB(5.6MB代码,5.6MB数据),位处理速度30ns,集成接口:1. MPI/DP, 2. PROFIBUS DP, 3. 可扩展的IF964-DP(IF1)接口 SIMATIC S7-400 控制器 标准DP版控制器 6ES74121XJ050AB0 CPU 412-1DP: 288KB(144KB代码,144KB数据),位处理速度75ns,集成MPI/DP接口 6ES74122XJ050AB0 CPU 412-2DP: 512KB(256KB代码,256KB数据),位处理速度75ns,集成接口:1. MPI/DP, 2. PROFIBUS DP 6ES74142XK050AB0 CPU 414-2DP: 1MB(512KB代码,512KB数据),位处理速度45ns,集成接口:1. MPI/DP, 2. PROFIBUS DP 6ES74143XM050AB0 CPU 414-3DP: 2.8MB(1.4MB代码,1.4MB数据),位处理速度45ns,集成接口:1. MPI/DP, 2. PROFIBUS DP, 3. 可扩展的IF964-DP(IF1)接口 6ES74162XN050AB0 CPU 416-2DP: 5.6MB(2.8MB代码,2.8MB数据),位处理速度30ns,集成接口:1. MPI/DP, 2. PROFIBUS DP 6ES74163XR050AB0 CPU 416-3DP: 11.2MB(5.6MB代码,5.6MB数据),位处理速度30ns,集成接口:1. MPI/DP, 2. PROFIBUS DP, 3. 可扩展的IF964-DP(IF1)接口 6ES74174XT050AB0 CPU 417-4DP: 30MB(15MB代码,15MB数据),位处理速度18ns,集成接口:1. MPI/DP, 2. PROFIBUS DP, 3~4.可扩展的IF964-DP(IF1)接口 标准PN版控制器 6ES74122EK060AB0 CPU 412-2PN: 1MB(0.5MB代码,0.5MB数据),位处理速度75ns,集成接口:1. MPI/DP, 2. ETHERNET/PROFINET 6ES74143EM060AB0 CPU 414-3PN: 4MB(2MB代码,2MB数据),位处理速度45ns,集成接口:1. MPI/DP, 2. PROFINET, 3. 可扩展的IF964-DP(IF1)接口 6ES74163ES060AB0 CPU 416-3PN: 16MB(8MB代码,8MB数据),位处理速度30ns,集成接口:1. MPI/DP, 2. PROFINET, 3. 可扩展的IF964-DP(IF1)接口 冗余控制器 6ES74125HK060AB0 CPU 412-5H:1 MB (512 KB数据,512 KB代码),位处理速度31.25ns,用于S7-400H和S7-400F/FH,集成 5个接口:1. MPI/DP, 2.PROFIBUS DP, 3. PRPFONET, 4~5. 2个用于同步模块的接口 6ES74145HM060AB0 CPU 414-5H:4MB (2MB数据,2 MB代码),位处理速度18.75ns,用于S7-400H和S7-400F/FH,集成 5个接口: 1. MPI/DP, 2. PROFIBUS DP, 3.PROFINET, 4~5. 2个用于同步模块的接口 6ES74165HS060AB0 CPU 416-5H:16 MB (10 MB数据,6 MB代码),位处理速度12.5ns,用于S7-400H和S7-400F/FH,集成 5个接口:1. MPI/DP, 2. PROFIBUS DP, 3. PROFINET, 4~5. 2个用于同步模块的接口 6ES74175HT060AB0 CPU 417-5H: 32 MB (16 MB数据,16 MB代码),位处理速度7.5ns,用于S7-400H和S7-400F/FH,集成 5个接口:1. MPI/DP, 2. PROFIBUS DP, 3. PROFINET, 4~5. 2个用于同步模块的接口 CPU 416-2, CPU 416-3 and CPU 416-3 PN/DP are powerful SIMATIC S7-400 CPUs. The integrated PROFIBUS DP interfaces in the CPU 416-2 and CPU 416-3 make it possible to connect directly to the PROFIBUS DP fieldbus as a master or slave. An additional DP master system can be connected to the CPU 416-3 and CPU 416-3 PN/DP using the IF 964-DP interface module. The integrated PROFINET interface of the CPU 416-3 PN/DP includes switch functionality when the ERTEC 400-ASIC is used. This forms the basis for providing two externally accessible PROFINET ports. In addition to hierarchical network topologies, this also enables the creation of line structures in the new S7-400 controllers. Note: Only the 6ES7 964-2AA04-0AB0 interface submodule may be used. Design Both CPUs are equipped with the following: Powerful processor: The CPUs achieve instruction execution times as low as 0.03 μs per binary instruction. CPU 416-2: 5.6 MB RAM (of which 2.8 MB each for program and data); CPU 416-3: 11.2 MB RAM (of which 5.6 MB each for program and data); CPU 416-3 PN/DP: 11.2 MB RAM (of which 5.6 MB each for program and data); fast RAM for parts of the user program relevant to execution. Flexible expansion: Up to 262144 digital and 16384 analog inputs/outputs. Multi-point interface MPI: With the MPI it is possible to establish simple networking of max. 32 stations at a data transmission rate of up to 12 Mbit/s. The CPUs can establish up to 44 connections to stations of the communications bus (C bus) and the MPI. Mode selector switch: Designed as toggle switch. Diagnostics buffer: The last 120 fault and interrupt events are retained in a ring buffer for diagnostic purposes. The number of entries can be parameterized. Real-time clock: The date and time are appended to diagnostic messages of the CPU. Memory card: For expansion of the integrated load memory. RAM and FEPROM cards (FEPROM for retentive storage) are available Combined MPI/DP interface and integrated PROFIBUS DP interface (CPU 416-2 and CPU 416-3): The PROFIBUS DP master interface allows a distributed automation configuration offering high speed and ease of use. From the user's point of view, the distributed I/O is treated as central I/O (same configuring, addressing and programming). Mixed configuration: SIMATIC S5 and SIMATIC S7 as PROFIBUS master according to EN 50170. CPU 416-3 and CPU 416-3 PN/DP also include: A module slot: An additional PROFIBUS DP master system can be connected via the IF 964-DP interface module. CPU 416-3 PN/DP additionally includes: PROFINET interface with 2 ports (switch): PROFINET I/O, 256 IO devices connectable PROFINET CBA Functions Block protection: A password concept protects the user program from unauthorized access. Integral HMI services: The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system. Integrated communications functions: PG/OP communication Shared data communication S7 standard communication S7 communication Firmware update using network CPU 416-3 PN/DP additional: Open communication over TCP/IP, UDP and ISO-on-TCP (RFC1006) Distributed intelligence in Component Based Automation (CBA) on PROFINET Additional diagnostic options with integrated web server Parameterizable attributes The STEP 7 tool "Hardware Configuration" can be used to program the properties and response of the S7-400 including the CPUs, e.g. Multi-point interface MPI: Definition of station addresses. Startup/cycle behavior Stipulation of the maximum cycle time and communications load Address assignment: Addressing of I/O modules. Retentive ranges: Definition of the number of retentive bit memories, counters, timers, data blocks and clock memories. Size of the process image, local data. Length of the diagnostics buffer Protection level: Definition of access authorization for program and data System diagnostics: Definition of the handling and scope of diagnostic messages Timed interrupts: Setting of periodicity CPU 416-3 PN/DP additional: PROFINET interface Parameterization of time synchronization using NTP procedure Indication and information functions Status and error indicators: LEDs indicate internal and external errors and operating states such as RUN, STOP, Restart, Test function, for example Test functions: The programming device can be used to display ** states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components Information functions: The programming device can be used to provide the user with information on the memory capacity and operating mode of the CPU and the current utilization of the working and load memories